Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 57
Filter
1.
Rev. panam. salud pública ; 47: e158, 2023. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1536666

ABSTRACT

ABSTRACT The objectives of this article are to reflect on the rationale behind the use of echocardiographic screening for rheumatic heart disease and to provide key recommendations about steps needed to implement and improve echocardiographic screening programs in Latin America. Rheumatic heart disease remains a public health problem affecting mainly low-income and lower-middle-income countries and populations. Latin America is an area with economic inequalities, and the epidemiology of rheumatic heart disease remains largely unknown. Echocardiographic screening is useful for updating the epidemiology and providing early diagnosis of the disease. We discuss different approaches used in successful echocardiographic screening programs worldwide and in Latin America. We then identify the key elements needed to establish successful echocardiographic screening programs in Latin America, including increased awareness and involvement from multiple sectors (e.g. the community, health care professionals, scientific organizations and public health entities), identification of areas in need, development of a plan and structure that include different screening approaches, and how to ensure appropriate follow up for those who screen positive.


RESUMEN Los objetivos de este artículo son reflexionar sobre los fundamentos que justifican el uso del tamizaje ecocardiográfico para detectar la cardiopatía reumática y ofrecer algunas recomendaciones importantes sobre los pasos que habría que dar para poner en marcha programas de tamizaje ecocardiográfico y mejorar los existentes en América Latina. La cardiopatía reumática sigue siendo un problema de salud pública que afecta principalmente a países y grupos poblacionales de ingresos bajos y medianos bajos. América Latina es una región de grandes desigualdades económicas y las características epidemiológicas de la cardiopatía reumática siguen siendo desconocidas en gran medida. El tamizaje ecocardiográfico resulta útil para actualizar los datos epidemiológicos y posibilitar un diagnóstico temprano de la enfermedad. En este artículo se analizan los diferentes enfoques empleados en algunos programas de tamizaje ecocardiográfico eficaces de distintas partes del mundo, incluida América Latina. A continuación se determinan los elementos clave necesarios para establecer programas eficaces de tamizaje ecocardiográfico en América Latina, incluida una mayor concientización y participación de diversos sectores (p. ej., la comunidad, los profesionales de salud, las organizaciones científicas y las entidades de salud pública), la identificación de las zonas más necesitadas, la elaboración de un plan y una estructura que incluyan diferentes abordajes del tamizaje, y el modo de garantizar un seguimiento adecuado de aquellas personas con un resultado positivo en el tamizaje.


RESUMO Os objetivos deste artigo são oferecer observações sobre a fundamentação do uso da triagem ecocardiográfica para doença cardíaca reumática e fornecer recomendações importantes sobre as etapas necessárias para implementar e melhorar os programas de triagem ecocardiográfica na América Latina. A doença cardíaca reumática continua sendo um problema de saúde pública que afeta principalmente países e populações de renda baixa e média-baixa. A América Latina é uma área com desigualdades econômicas, e a epidemiologia da doença cardíaca reumática continua amplamente desconhecida. A triagem ecocardiográfica serve para atualizar a epidemiologia e proporcionar o diagnóstico precoce da doença. Examinamos as diferentes abordagens usadas em programas de triagem ecocardiográfica bem-sucedidos em todo o mundo e na América Latina. Em seguida, identificamos os principais elementos necessários para estabelecer programas de triagem ecocardiográfica com sucesso na América Latina. Tais programas incluiriam maior conscientização e envolvimento de vários setores (por exemplo, a comunidade, profissionais de saúde, organizações científicas e entidades de saúde pública), identificação de áreas carentes, desenvolvimento de um plano e estrutura abrangendo diferentes abordagens de triagem e formas de garantir o seguimento adequado de pessoas com resultado positivo na triagem.

7.
Arq. bras. cardiol ; 110(4): 312-320, Apr. 2018. tab, graf
Article in English | LILACS | ID: biblio-888058

ABSTRACT

Abstract Background: Atrial fibrillation frequently affects patients with valvular heart disease. Ablation of atrial fibrillation during valvular surgery is an alternative for restoring sinus rhythm. Objectives: This study aimed to evaluate mid-term results of successful atrial fibrillation surgical ablation during valvular heart disease surgery, to explore left atrium post-ablation mechanics and to identify predictors of recurrence. Methods: Fifty-three consecutive candidates were included. Eligibility criteria for ablation included persistent atrial fibrillation <10 years and left atrium diameter < 6.0 cm. Three months after surgery, echocardiogram, 24-hour Holter monitoring and electrocardiograms were performed in all candidates who maintained sinus rhythm (44 patients). Echo-study included left atrial deformation parameters (strain and strain rate), using 2-dimensional speckle-tracking echocardiography. Simultaneously, 30 healthy individuals (controls) were analyzed with the same protocol for left atrial performance. Significance was considered with a P value of < 0.05. Results: After a mean follow up of 17 ± 2 months, 13 new post-operative cases of recurrent atrial fibrillation were identified. A total of 1,245 left atrial segments were analysed. Left atrium was severely dilated in the post-surgery group and, mechanical properties of left atrium did not recover after surgery when compared with normal values. Left atrial volume (≥ 64 mL/m2) was the only independent predictor of atrial fibrillation recurrence (p = 0.03). Conclusions: Left atrial volume was larger in patients with atrial fibrillation recurrence and emerges as the main predictor of recurrences, thereby improving the selection of candidates for this therapy; however, no differences were found regarding myocardial deformation parameters. Despite electrical maintenance of sinus rhythm, left atrium mechanics did not recover after atrial fibrillation ablation performed during valvular heart disease surgery.


Resumo Fundamento: A fibrilação atrial frequentemente afeta pacientes com doenças das valvas cardíacas. A ablação da fibrilação atrial durante a cirurgia das válvulas é uma alternativa para restaurar o ritmo sinusal. Objetivos: Este estudo teve como objetivos avaliar resultados em médio prazo da ablação cirúrgica bem sucedida da FA durante cirurgia para doença valvar, para explorar a mecânica do AE após a ablação e identificar preditores de recorrência. Métodos: Foram incluídos 53 candidatos consecutivos. Os critérios de elegibilidade para ablação foram fibrilação atrial persistente <10 anos e diâmetro do átrio esquerdo < 6 cm. Três meses após a cirurgia, foram realizados ecocardiografia, Holter por 24 horas, e eletrocardiografias em todos os candidatos que mantiveram o ritmo sinusal (44 pacientes). O estudo eco incluiu parâmetros de deformação ao átrio esquerdo (strain e taxa de strain) usando ecocardiografia bidimensional com speckle tracking. Simultaneamente, 30 indivíduos sadios (controles) foram analisados com o mesmo protocolo para o desempenho do átrio esquerdo. Um valor de P < 0,05 foi considerado significativo. Resultados: Após um período médio de acompanhamento de 17 ± 2 meses, 13 novos casos de fibrilação atrial no pós-operatório foram identificados. Um total de 1245 segmentos do átrio esquerdo foi analisado. O grupo pós-cirúrgico apresentou dilatação grave do átrio esquerdo, e as propriedades mecânicas do átrio esquerdo não se recuperaram após a cirurgia quando comparadas com valores normais. O volume do átrio esquerdo (≥ 64 mL/m2) foi o único preditor independente de recorrência de fibrilação atrial (p = 0,03). Conclusões: O volume do átrio esquerdo foi maior nos pacientes com fibrilação atrial recorrente, e desponta como o principal preditor de recorrência, melhorando, assim, a seleção de candidatos para essa terapia. No entanto, não foram encontradas diferenças em relação aos parâmetros de deformação do miocárdio. Apesar da manutenção elétrica do ritmo sinusal, a função mecânica do átrio esquerdo não se recuperou após a ablação da fibrilação atrial realizada durante a cirurgia para doença da valva cardíaca.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Atrial Fibrillation/surgery , Atrial Fibrillation/diagnostic imaging , Cryosurgery/methods , Heart Valve Diseases/surgery , Heart Valve Diseases/diagnostic imaging , Recurrence , Atrial Fibrillation/physiopathology , Time Factors , Echocardiography/methods , Prospective Studies , Reproducibility of Results , Risk Factors , Follow-Up Studies , Atrial Function, Left/physiology , Treatment Outcome , Statistics, Nonparametric , Electrocardiography , Heart Atria/surgery , Heart Atria/physiopathology , Heart Atria/diagnostic imaging , Heart Rate/physiology , Heart Valve Diseases/physiopathology
8.
Arq. bras. cardiol ; 109(4): 348-356, Oct. 2017. tab, graf
Article in English | LILACS | ID: biblio-887953

ABSTRACT

Abstract Background: The prevalence of coronary artery disease (CAD) in valvular patients is similar to that of the general population, with the usual association with traditional risk factors. Nevertheless, the search for obstructive CAD is more aggressive in the preoperative period of patients with valvular heart disease, resulting in the indication of invasive coronary angiography (ICA) to almost all adult patients, because it is believed that coronary artery bypass surgery should be associated with valve replacement. Objectives: To evaluate the prevalence of obstructive CAD and factors associated with it in adult candidates for primary heart valve surgery between 2001 and 2014 at the National Institute of Cardiology (INC) and, thus, derive and validate a predictive obstructive CAD score. Methods: Cross-sectional study evaluating 2898 patients with indication for heart surgery of any etiology. Of those, 712 patients, who had valvular heart disease and underwent ICA in the 12 months prior to surgery, were included. The P value < 0.05 was adopted as statistical significance. Results: The prevalence of obstructive CAD was 20%. A predictive model of obstructive CAD was created from multivariate logistic regression, using the variables age, chest pain, family history of CAD, systemic arterial hypertension, diabetes mellitus, dyslipidemia, smoking, and male gender. The model showed excellent correlation and calibration (R² = 0.98), as well as excellent accuracy (ROC of 0.848; 95%CI: 0.817-0.879) and validation (ROC of 0.877; 95%CI: 0.830 - 0.923) in different valve populations. Conclusions: Obstructive CAD can be estimated from clinical data of adult candidates for valve repair surgery, using a simple, accurate and validated score, easy to apply in clinical practice, which may contribute to changes in the preoperative strategy of acquired heart valve surgery in patients with a lower probability of obstructive disease.


Resumo Fundamento: A prevalência de doença arterial coronariana (DAC) nos pacientes valvares é semelhante à da população geral, com associação usual aos fatores de risco tradicionais. Ainda assim, a busca por DAC obstrutiva é mais agressiva nos valvulopatas em pré-operatório, determinando a angiografia coronariana invasiva (ACI) a praticamente todos os pacientes adultos, uma vez que se acredita que a cirurgia de revascularização miocárdica deva ser associada à troca valvar. Objetivos: Avaliar a prevalência de DAC obstrutiva e identificar fatores a ela associados em adultos candidatos à cirurgia cardíaca primariamente valvar entre os anos de 2001 a 2014 no Instituto Nacional de Cardiologia (INC) e elaborar um modelo preditivo de DAC obstrutiva através de escore derivado de análise multivariada. A partir da estimativa da probabilidade pré-teste de DAC obstrutiva, espera-se melhor estratégia pré-operatória para cada paciente. Métodos: Estudo transversal avaliando 2.898 pacientes com indicação de cirurgia cardíaca por qualquer etiologia. Desses, foram estudados 712 pacientes valvopatas submetidos à ACI nos 12 meses anteriores à cirurgia. Diferenças com valor de p < 0,05 foram consideradas estatisticamente significativas. Resultados: A prevalência de DAC obstrutiva foi de 20%. Um modelo preditivo de DAC obstrutiva foi criado a partir de regressão logística multivariada, utilizando as variáveis idade, dor torácica, história familiar de DAC, hipertensão arterial sistêmica, diabetes mellitus, dislipidemia, tabagismo e sexo masculino. O modelo demonstrou excelente correlação e calibração (R2 = 0,98), além de ótima acurácia (ROC de 0,848; IC95% 0,817 - 0,879) e validação em diferente população valvar (ROC de 0,877; IC 95%: 0,830 - 0,923). Conclusões: É possível estimar DAC obstrutiva a partir de dados clínicos com elevada acurácia, o que pode vir a permitir estabelecer estratégias pré-operatórias de acordo com a probabilidade pré-teste individual, evitando a indicação indiscriminada de procedimentos desnecessários e invasivos, principalmente nos grupos de menor probabilidade de DAC obstrutiva. (Arq Bras Cardiol. 2017; [online].ahead print, PP.0-0)


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Coronary Artery Disease/etiology , Coronary Artery Disease/epidemiology , Risk Assessment/methods , Heart Valve Diseases/surgery , Heart Valve Diseases/complications , Reference Standards , Brazil/epidemiology , Logistic Models , Prevalence , Cross-Sectional Studies , Multivariate Analysis , Reproducibility of Results , Retrospective Studies , Risk Factors , Sensitivity and Specificity , Coronary Angiography , Preoperative Period , Heart Valve Diseases/epidemiology
9.
Arq. bras. cardiol ; 108(4): 347-353, Apr. 2017. tab, graf
Article in English | LILACS | ID: biblio-838728

ABSTRACT

Abstract Background: The knowledge of the variables predicting mortality is important in clinical practice and for therapeutic monitoring in mitral valve disease. Objectives: To determine whether a quality of life score evaluated with the Functional Evaluation of Cardiac Health questionnaire would predict mortality in dogs with degenerative mitral valve disease (DMVD). Methods: Thirty-six client-owned dogs with mitral valve disease underwent clinical, laboratory, and echocardiographic evaluations at baseline and were monitored for 6 months. Cardiovascular death was the primary outcome. Results: The 36 dogs were classified as survivors or nonsurvivors. Higher values of the following variables were obtained at baseline in the nonsurviving group (12 dogs): amino-terminal pro-B-type natriuretic peptide (NT-proBNP) levels, plasma norepinephrine, heart rate, quality of life score, diastolic left ventricular internal dimension to aortic root ratio, systolic left ventricular internal dimension to aortic root ratio, and left atrium to aortic root ratio. NT-proBNP levels and quality life score were independently associated with death in the multivariable analysis. Conclusion: The quality life score was an independent variable for cardiac death in dogs with DMVD. This result is encouraging, as this score is easy to apply and does not require any technology, only a veterinarian and an observant owner.


Resumo Fundamento: O conhecimento das variáveis preditoras de mortalidade é importante para a prática clínica e para o acompanhamento terapêutico na doença da valva mitral. Objetivos: Determinar se um escore de qualidade de vida avaliado com o Functional Evaluation of Cardiac Health poderia auxiliar na predição de mortalidade em cães com doença degenerativa da valva mitral (DDVM). Métodos: Trinta e seis cães de estimação com doença valvar mitral foram submetidos a avaliação clínica, laboratorial e ecocardiográfica no início do estudo e monitorizados durante 6 meses. A morte cardiovascular foi o desfecho primário. Resultados: Os 36 cães foram classificados como sobreviventes ou não sobreviventes. Os valores mais elevados das seguintes variáveis foram obtidos no início do estudo no grupo de não sobreviventes (12 cães): fragmento N-terminal do peptídeo natriurético tipo B (NT-proBNP), norepinefrina plasmática, frequência cardíaca, escore de qualidade de vida, razão da dimensão interna diastólica do ventrículo esquerdo e raiz aórtica, razão da dimensão interna sistólica do ventrículo esquerdo e raiz aórtica e a relação da dimensão do átrio esquerdo e a raiz aórtica. Concentrações de NT-proBNP e o escore de qualidade de vida foram independentemente associados com morte na análise multivariada. Conclusão: O escore de qualidade de vida foi uma variável independente para a morte por doença cardíaca em cães com DDVM. Este resultado é encorajador, pois este escore é de fácil aplicação e não requer o emprego de tecnologia, necessitando apenas de um veterinário e um dono observador.


Subject(s)
Animals , Male , Female , Dogs , Quality of Life , Dog Diseases/mortality , Heart Valve Diseases/veterinary , Mitral Valve/abnormalities , Peptide Fragments/blood , Norepinephrine/blood , Prospective Studies , Surveys and Questionnaires , Natriuretic Peptide, Brain/blood , Heart Rate , Heart Valve Diseases/mortality
10.
Arq. bras. cardiol ; 107(1): 55-62, July 2016. tab, graf
Article in English | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: lil-792497

ABSTRACT

Abstract Background: Paravalvular regurgitation (paravalvular leak) is a serious and rare complication associated with valve replacement surgery. Studies have shown a 3% to 6% incidence of paravalvular regurgitation with hemodynamic repercussion. Few studies have compared surgical and percutaneous approaches for repair. Objectives: To compare the surgical and percutaneous approaches for paravalvular regurgitation repair regarding clinical outcomes during hospitalization and one year after the procedure. Methods: This is a retrospective, descriptive and observational study that included 35 patients with paravalvular leak, requiring repair, and followed up at the Dante Pazzanese Institute of Cardiology between January 2011 and December 2013. Patients were divided into groups according to the established treatment and followed up for 1 year after the procedure. Results: The group submitted to percutaneous treatment was considered to be at higher risk for complications because of the older age of patients, higher prevalence of diabetes, greater number of previous valve surgeries and lower mean creatinine clearance value. During hospitalization, both groups had a large number of complications (74.3% of cases), with no statistical difference in the analyzed outcomes. After 1 year, the percutaneous group had a greater number of re-interventions (8.7% vs 20%, p = 0.57) and a higher mortality rate (0% vs. 20%, p = 0.08). A high incidence of residual mitral leak was observed after the percutaneous procedure (8.7% vs. 50%, p = 0.08). Conclusion: Surgery is the treatment of choice for paravalvular regurgitation. The percutaneous approach can be an alternative for patients at high surgical risk.


Resumo Fundamento: Regurgitação ou escape paravalvar é uma complicação grave e incomum associada ao implante de prótese valvar. Estudos mostram incidência de 3% a 6% com repercussão hemodinâmica. Existem poucos estudos na literatura que comparam as abordagens cirúrgica e percutânea para sua correção. Objetivos: Comparar as abordagens cirúrgica e percutânea de correção da regurgitação paravalvar quanto a desfechos clínicos durante a internação e após 1 ano do procedimento. Métodos: Este é um estudo retrospectivo, descritivo e observacional, que incluiu 35 pacientes com escape paravalvar acompanhados no Instituto Dante Pazzanese de Cardiologia entre janeiro de 2011 e dezembro de 2013 e que necessitaram de correção. Os pacientes foram divididos de acordo com o tratamento estabelecido e acompanhados por um período 1 ano após o procedimento. Resultados: O grupo submetido ao tratamento percutâneo foi considerado como de maior risco para complicações por apresentar pacientes mais idosos, com maior prevalência de diabetes, maior quantidade de cirurgias valvares prévias e menor valor médio de clearance de creatinina. Durante a evolução intra-hospitalar, observou-se grande número de complicações nos dois grupos (74,3% dos casos), sem diferença estatística nos desfechos analisados. Após 1 ano, o grupo percutâneo teve maior número de reintervenções (8,7% vs. 20%, p = 0,57) e mortalidade maior (0% vs. 20%, p = 0,08). Uma alta incidência de escape residual mitral foi verificada após procedimento percutâneo (8,7% vs. 50%, p = 0,08). Conclusão: A cirurgia é o tratamento de escolha da regurgitação paravalvar. A abordagem percutânea pode ser uma alternativa para os pacientes com risco cirúrgico elevado.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/etiology , Heart Valve Prosthesis Implantation/adverse effects , Percutaneous Coronary Intervention/methods , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/etiology , Aortic Valve/surgery , Aortic Valve Insufficiency/mortality , Postoperative Complications/surgery , Postoperative Complications/mortality , Reoperation , Time Factors , Bioprosthesis/adverse effects , Heart Valve Prosthesis/adverse effects , Retrospective Studies , Risk Factors , Treatment Outcome , Echocardiography, Transesophageal , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/mortality , Therapeutic Occlusion/methods , Therapeutic Occlusion/mortality , Percutaneous Coronary Intervention/mortality , Hospitalization , Mitral Valve/surgery , Mitral Valve Insufficiency/mortality
11.
Arq. bras. cardiol ; 106(5): 367-372, May 2016. tab, graf
Article in English | LILACS | ID: lil-784170

ABSTRACT

Abstract Background: Isolated cleft mitral valve (ICMV) may occur alone or in association with other congenital heart lesions. The aim of this study was to describe the profile of cardiac lesions associated with ICMV and their potential impact on therapeutic management. Methods: We conducted a descriptive study with data retrieved from the Congenital Heart Disease (CHD) single-center registry of our institution, including patients with ICMV registered between December 2008 and November 2014. Results: Among 2177 patients retrieved from the CHD registry, 22 (1%) had ICMV. Median age at diagnosis was 5 years (6 days to 36 years). Nine patients (40.9%) had Down syndrome. Seventeen patients (77.3%) had associated lesions, including 11 (64.7%) with accessory chordae in the left ventricular outflow tract (LVOT) with no obstruction, 15 (88.2%) had ventricular septal defect (VSD), three had secundum atrial septal defect, and four had patent ductus arteriosus. Thirteen patients (59.1%) required surgical repair. The decision to proceed with surgery was mainly based on the severity of the associated lesion in eight patients (61.5%) and on the severity of the mitral regurgitation in four patients (30.8%). In one patient, surgery was decided based on the severity of both the associated lesion and mitral regurgitation. Conclusion: Our study shows that ICMV is rare and strongly associated with Down syndrome. The most common associated cardiac abnormalities were VSD and accessory chordae in the LVOT. We conclude that cardiac lesions associated with ICMV are of major interest, since in this study patients with cardiac lesions were diagnosed earlier. The decision to operate on these patients must take into account the severity of both mitral regurgitation and associated cardiac lesions.


Resumo Fundamento: A fissura isolada da valva mitral (FIVM) pode ocorrer isoladamente ou em associação com outras lesões cardíacas congênitas. O objetivo deste estudo foi descrever o perfil das lesões cardíacas associadas à FIVM e o potencial impacto dessas lesões na terapêutica. Métodos: Realizamos um estudo descritivo com dados obtidos do registro unicêntrico Congenital Heart Disease (CHD) de nossa instituição incluindo pacientes com FIVM registrados entre dezembro de 2008 e novembro de 2014. Resultados: Entre 2177 pacientes identificados no registro CHD, 22 (1%) apresentavam FIVM. A mediana de idade ao diagnóstico foi de 5 anos (6 dias a 36 anos). Nove pacientes (40,9%) apresentavam síndrome de Down. Dezessete pacientes (77,3%) apresentavam lesões associadas, incluindo 11 (64,7%) com cordoalha acessória na via de saída do ventrículo esquerdo (VSVE) sem obstrução, 15 (88,2%) com comunicação interventricular (CIV), três com comunicação interatrial do tipo ostium secundum e quatro com persistência do canal arterial. Treze pacientes (59,1%) necessitaram reparo cirúrgico. A decisão de prosseguir com a cirurgia foi baseada principalmente na gravidade da lesão associada em oito pacientes (61,5%) e na gravidade da regurgitação mitral em quatro pacientes (30,8%). Em um paciente, a decisão por cirurgia foi baseada na gravidade tanto da lesão associada quanto da regurgitação mitral. Conclusão: Nosso estudo mostra que a FIVM é rara e está fortemente associada à síndrome de Down. As anormalidades cardíacas associadas mais comuns foram a CIV e cordoalha acessória na VSVE. Concluímos que as lesões cardíacas associadas à FIVM são de grande interesse, já que neste estudo, pacientes com lesões associadas foram diagnosticados mais precocemente. A decisão cirúrgica deve levar em conta a gravidade tanto da regurgitação mitral quanto das lesões cardíacas associadas.


Subject(s)
Humans , Male , Female , Infant, Newborn , Infant , Child, Preschool , Child , Adolescent , Adult , Young Adult , Heart Defects, Congenital/complications , Mitral Valve/abnormalities , Mitral Valve Insufficiency/complications , Severity of Illness Index , Echocardiography, Doppler, Color , Heart Atria/abnormalities , Heart Defects, Congenital/surgery , Heart Septal Defects, Atrial/surgery , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/diagnostic imaging
12.
Rev. bras. enferm ; 69(1): 40-46, jan.-fev. 2016. tab
Article in English | LILACS, BDENF | ID: lil-771967

ABSTRACT

RESUMO Objetivo: analisar as características sociodemográficas e clínicas dos pacientes com valvopatia e verificar a influência dessas variáveis no impacto da valvopatia no cotidiano. Método: participaram do estudo 86 pacientes em seguimento ambulatorial. A coleta de dados foi realizada em duas etapas - entrevista presencial para caracterização sociodemográfica e clínica e por meio de contato telefônico para aplicação do Instrumento para Mensuração do Impacto da Doença no Cotidiano do Valvopata (IDCV). Os dados foram analisados através de estatística descritiva e análise de regressão múltipla. Resultados: constatou-se que o escore total do IDCV e seus domínios foram influenciados pela idade, escolaridade, presença ou não de sintomatologia, uso ou não de diurético. Conclusão: o impacto da doença foi influenciado por variáveis sociodemográficas e clínicas. Os resultados fornecem subsídios para o delineamento de intervenções de enfermagem com vistas à redução do impacto da doença no cotidiano do paciente com valvopatia.


RESUMEN Objetivo: analizar las características sociodemográficas y clínicas de los pacientes con enfermedad de las válvulas del corazón y verificar la influencia de esas variables en el impacto de la enfermedad en la vida cotidiana. Método: participaron del estudio 86 pacientes con seguimiento ambulatorio. La recolección de datos fue realizada en dos etapas - entrevista presencial para caracterización sociodemográfica y clínica y por medio de contacto telefônico para aplicación del Instrumento para Medición del Impacto en lo Cotidiano de la Enfermedad de Válvula (IDCV). Los datos fueron analizados a través de estadística descriptiva y análisis de regresión múltiple. Resultados: se constató que la puntuación total del IDCV y sus dominios fueron influenciados por la edad, escolaridad, presencia o no de sintomatología, uso o no de diurético. Conclusión: el impacto de la enfermedad fue influenciado por variables sociodemográficas y clínicas. Los resultados otorgan subsidios para el delineamiento de intervenciones de enfermería con vistas a la reducción del impacto de la enfermedad en lo cotidiano del paciente con enfermedad de válvula.


ABSTRACT Objective: to analyze the sociodemographic and clinical characteristics of patients with valvular heart disease and to verify the influence of these variables on the impact of valve disease in daily life. Method: the study involved 86 outpatients. Data collection was performed in two stages - face-to-face interview for sociodemographic and clinical characterization and through telephone contact for the application of the Instrument to Measure the Impact of Valvular Heart Disease on Patient's Everyday Life (IDCV). Data were analyzed through descriptive statistics and multiple regression analysis. Results: it was noticed that the total score of IDCV and its domains were influenced by age, schooling, presence or absence of symptoms, use or not of diuretic. Conclusion: The impact of the disease was influenced by sociodemographic and clinical variables. The results provide subsidies for the design of nursing interventions aimed at reducing the impact of the disease on the patient's daily life with valve disease.


Subject(s)
Humans , Male , Female , Adult , Aged , Heart Valve Diseases/epidemiology , Social Class , Activities of Daily Living , Data Collection , Middle Aged
13.
Rev. latinoam. enferm. (Online) ; 24: e2730, 2016. tab
Article in English | LILACS, BDENF | ID: biblio-961069

ABSTRACT

ABSTRACT Objective: evaluate the practicality, acceptability and the floor and ceiling effects, estimate the reliability and verify the convergent construct's validity with the instrument called the Heart Valve Disease Impact on daily life (IDCV) of the valve disease in patients with mitral and or aortic heart valve disease. Method: data was obtained from 86 heart valve disease patients through 3 phases: a face to face interview for a socio-demographic and clinic characterization and then other two done through phone calls of the interviewed patients for application of the instrument (test and repeat test). Results: as for the practicality and acceptability, the instrument was applied with an average time of 9,9 minutes and with 110% of responses, respectively. Ceiling and floor effects observed for all domains, especially floor effect. Reliability was tested using the test - repeating pattern to give evidence of temporal stability of the measurement. Significant negative correlations with moderate to strong magnitude were found between the score of the generic question about the impact of the disease and the scores of IDCV, which points to the validity of the instrument convergent construct. Conclusion: the instrument to measure the impact of valve heart disease on the patient's daily life showed evidence of reliability and validity when applied to patients with heart valve disease.


RESUMO Objetivos: avaliar a praticabilidade, aceitabilidade e os efeitos teto e chão, estimar a confiabilidade e verificar a validade de construto convergente do Instrumento para Mensuração do Impacto da Doença no Cotidiano do Valvopata em pacientes com valvopatia mitral e/ou aórtica. Método: dados foram obtidos junto a 86 pacientes valvopatas por meio de três etapas: uma entrevista presencial para caracterização sociodemográfica e clínica e as duas outras realizadas por meio de contato telefônico para as aplicações do instrumento (Teste e teste de repetição). Resultados: quanto à praticabilidade e aceitabilidade, o instrumento foi aplicado com tempo médio de 9,9 minutos e com 110% de respostas, respectivamente. Constatados efeitos teto e chão para todos os domínios, principalmente efeito chão. A confiabilidade foi testada por meio do teste-teste de repetição, obtendo-se evidências de estabilidade temporal da medida. Foram constatadas correlações negativas significantes de moderada a forte magnitude entre o escore da questão genérica sobre o impacto da doença e os escores do IDCV, o que aponta para validade de construto convergente do instrumento. Conclusão: o Instrumento para Mensuração do Impacto da Doença no Cotidiano do Valvopata apresentou evidências de confiabilidade e validade quando aplicado em pacientes com valvopatia.


RESUMEN Objetivos: evaluar la viabilidad, aceptabilidad y los efectos techo y suelo, estimar la confiabilidad y verificar la validez de constructo convergente del Instrumento para Medir el Impacto en lo Cotidiano (IDCV) del sujeto con valvulopatías mitral y/o aórtica. Método: los datos fueron obtenidos de 86 pacientes con valvulopatías por medio de tres etapas: una entrevista presencial para caracterización sociodemográfica y clínica y las otras dos realizadas por medio de contacto telefónico para las aplicaciones del instrumento (test y test de repetición). Resultados: en cuanto a la viabilidad y aceptabilidad, el instrumento fue aplicado con un tiempo promedio de 9,9 minutos y con 110% de respuestas, respectivamente. Fueron constatados los efectos techo y suelo para todos los dominios, principalmente el efecto suelo. La confiabilidad fue comprobada por medio del test de repetición, obteniéndose evidencias de estabilidad temporal de la medida. Fueron constatadas correlaciones negativas significativas de moderada a fuerte magnitud entre el puntaje de la pregunta genérica sobre el impacto de la enfermedad y los puntajes del IDCV, lo que apunta para la validez de constructo convergente del instrumento. Conclusión: el instrumento para medir el impacto de la valvulopatía en lo cotidiano del sujeto, presentó evidencias de confiabilidad y validez cuando aplicado en pacientes con esa enfermedad.


Subject(s)
Humans , Male , Female , Middle Aged , Activities of Daily Living , Sickness Impact Profile , Reproducibility of Results , Heart Valve Diseases/diagnosis
18.
Arq. bras. cardiol ; 105(5): 450-456, Nov. 2015. tab, graf
Article in English | LILACS | ID: lil-765000

ABSTRACT

AbstractBackground:Risk scores for cardiac surgery cannot continue to be neglected.Objective:To assess the performance of “Age, Creatinine and Ejection Fraction Score” (ACEF Score) to predict mortality in patients submitted to elective coronary artery bypass graft and/or heart valve surgery, and to compare it to other scores.Methods:A prospective cohort study was carried out with the database of a Brazilian tertiary care center. A total of 2,565 patients submitted to elective surgeries between May 2007 and July 2009 were assessed. For a more detailed analysis, the ACEF Score performance was compared to the InsCor’s and EuroSCORE’s performance through correlation, calibration and discrimination tests.Results:Patients were stratified into mild, moderate and severe for all models. Calibration was inadequate for ACEF Score (p = 0.046) and adequate for InsCor (p = 0.460) and EuroSCORE (p = 0.750). As for discrimination, the area under the ROC curve was questionable for the ACEF Score (0.625) and adequate for InsCor (0.744) and EuroSCORE (0.763).Conclusion:Although simple to use and practical, the ACEF Score, unlike InsCor and EuroSCORE, was not accurate for predicting mortality in patients submitted to elective coronary artery bypass graft and/or heart valve surgery in a Brazilian tertiary care center. (Arq Bras Cardiol. 2015; [online].ahead print, PP.0-0).


ResumoFundamento:Escores de risco para cirurgia cardíaca não podem continuar sendo neglicenciados.Objetivo:Avaliar o desempenho do Age, Creatinine and Ejection Fraction Score (ACEF Score) na predição de mortalidade dos pacientes submetidos à cirurgia de revascularização miocárdica e/ou valvar eletiva, e compará-lo a outros escores.Métodos:Estudo de coorte prospectivo no banco de um centro terciário brasileiro. Foram avaliados 2.565 pacientes operados de maneira eletiva entre maio de 2007 e julho de 2009. Para uma análise mais detalhada, o desempenho do ACEF Score foi comparado ao do InsCor e ao do EuroSCORE por meio de testes de correlação, calibração e discriminação.Resultados:Os pacientes foram estratificados em leve, moderado e grave para todos os modelos. A calibração foi inadequada para o ACEF Score (p = 0,046) e adequada para o InsCor (p = 0,460) e o EuroSCORE (p = 0,750). Na discriminação, a área abaixo da curva ROC apresentou-se questionável para o ACEF Score (0,625) e apropriada para o InsCor (0,744) e o EuroSCORE (0,763).Conclusão:Embora simples e prático, o ACEF Score, ao contrário do InsCor e do EuroSCORE, não se mostrou acurado para predizer mortalidade nos pacientes submetidos à cirurgia de revascularização miocárdica e/ou valvar eletiva em centro terciário brasileiro. (Arq Bras Cardiol. 2015; [online].ahead print, PP.0-0).


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Coronary Artery Bypass/mortality , Creatinine/blood , Heart Valve Prosthesis Implantation/mortality , Risk Assessment/methods , Stroke Volume/physiology , Age Factors , Brazil , Calibration , Epidemiologic Methods , Elective Surgical Procedures/mortality , Heart Valve Diseases/mortality , Heart Valve Diseases/surgery , Models, Theoretical , Reference Values , Severity of Illness Index , Tertiary Care Centers/statistics & numerical data
19.
Rev. bras. cir. cardiovasc ; 30(4): 449-458, July-Aug. 2015. tab
Article in English | LILACS | ID: lil-763167

ABSTRACT

AbstractObjective:To evaluate the influence of pulmonary hypertension in the ultra-fast-track anesthesia technique in adult cardiac surgery.Methods:A retrospective study. They were included 40 patients divided into two groups: GI (without pulmonary hypertension) and GII (with pulmonary hypertension). Based on data obtained by transthoracic echocardiography. We considered as the absence of pulmonary hypertension: a pulmonary artery systolic pressure (sPAP) <36 mmHg, with tricuspid regurgitation velocity <2.8 m/s and no additional echocardiographic signs of PH, and PH as presence: a sPAP >40 mmHg associated with additional echocardiographic signs of PH. It was established as influence of pulmonary hypertension: the impossibility of extubation in the operating room, the increase in the time interval for extubation and reintubation the first 24 hours postoperatively. Univariate and multivariate analyzes were performed when necessary. Considered significant a P value <0.05.Results:The GI was composed of 21 patients and GII for 19. All patients (100%) were extubated in the operating room in a medium time interval of 17.58±8.06 min with a median of 18 min in GII and 17 min in GI. PH did not increase the time interval for extubation (P=0.397). It required reintubation of 2 patients in GII (5% of the total), without statistically significant as compared to GI (P=0.488).Conclusion:In this study, pulmonary hypertension did not influence on ultra-fast-track anesthesia in adult cardiac surgery.


ResumoObjetivo:Avaliar a influência da hipertensão pulmonar na técnica anestésica ultra-fast-track em cirurgia cardíaca de adultos.Métodos:Estudo retrospectivo. Foram incluídos 40 pacientes divididos em dois grupos: GI (sem hipertensão pulmonar) e GII (com hipertensão pulmonar). Com base em dados obtidos por ecocardiograma transtorácico, considerou-se como ausência de hipertensão pulmonar: uma pressão sistólica da artéria pulmonar 36 mmHg, com velocidade de regurgitação tricúspide <2,8 m/s e ausência de sinais ecocardiográficos adicionais de hipertensão pulmonar; e como presença de hipertensão pulmonar: uma PSAP >40 mmHg associada a sinais ecocardiográficos adicionais de hipertensão pulmonar. Foi estabelecida como influência da HP: a impossibilidade de extubação na sala cirúrgica, o aumento no intervalo de tempo para extubação e a necessidade de reintubação nas primeiras 24h de pós-operatório. Foram realizadas análises univariada e multivariada quando necessário. Foi considerado como significativo um valor de P<0,05.Resultados:O GI foi composto por 21 pacientes e o GII por 19. Todos os pacientes (100%) foram extubados na sala cirúrgica em um intervalo de tempo médio de 17,58±8,06 min, com uma mediana de 18 min no GI e 17 min no GII. A hipertensão pulmonar não aumentou o intervalo de tempo para extubação (P=0,397). Foi necessária a reintubação de 2 pacientes do GII (5% do total), estatisticamente sem significância em relação ao GI (P=0,488). Não houve óbitos durante a internação dos pacientes.Conclusão:Neste estudo a hipertensão pulmonar não teve influência na técnica anestésica ultra-fast-track em cirurgia cardíaca de adultos.


Subject(s)
Adult , Female , Humans , Male , Young Adult , Anesthesia/methods , Hypertension, Pulmonary/surgery , Mitral Valve/surgery , Thoracic Surgical Procedures/methods , Airway Extubation , Echocardiography , Retrospective Studies , Time Factors
20.
Rev. bras. cir. cardiovasc ; 30(4): 425-432, July-Aug. 2015. tab, graf
Article in English | LILACS | ID: lil-763158

ABSTRACT

AbstractObjective:The aim of the current study was to evaluate the early experience of the application of transcatheter aortic valve implantation with the balloon-expandable system in China. The transcatheter aortic valve implantation technology has been widely used for patients with inoperable severe aortic stenosis in the developed world. The application of transcatheter aortic valve implantation is still in the early stages of testing in China, particularly for the balloon-expandable valve procedure.Methods:This was a retrospective study. All patients undergoing transcatheter aortic valve implantation with balloon-expandable system in our hospital between 2011 and 2014 were included. Edwards SAPIEN XT Transcatheter Heart Valve was used. The improvement of valve and heart function was evaluated as well as 30-day mortality and major complications according to the VARC-2 definition.Results:A total of 10 transcatheter aortic valve implantation procedures with the balloon-expandable system were performed in our hospital, of which 9 were transfemoral and 1 was transapical. The median age was 76 years, and the median STS score and Logistic EuroSCORE (%) were 8.9 and 16.2. The implantation was successfully conducted in all patients, only 2 patients had mild paravalvular leak. There was no second valve implantation. Moreover, no 30-day mortality or complications was reported. Following the transcatheter aortic valve implantation procedure, the heart and valve functions had improved significantly. During the follow-up period of 3-34 months, one patient died of lung cancer 13 months after the operation.Conclusion:This early experience has provided preliminary evidence for the safety and efficacy of transcatheter aortic valve implantation procedure with the balloon-expandable system in the developing world with an increasing aging population.


ResumoObjetivo:O objetivo do presente estudo foi avaliar a experiência inicial da aplicação do implante percutâneo da válvula aórtica com o sistema balão-expansível na China. A tecnologia TAVI tem sido amplamente utilizada para pacientes com estenose aórtica grave inoperável no mundo desenvolvido. A aplicação de implante percutâneo da válvula aórtica está ainda nas etapas iniciais de teste na China, em particular o procedimento de válvula balão-expansível.Métodos:O estudo foi retrospectivo e todos os pacientes submetidos a implante percutâneo da válvula aórtica com sistema balão-expansível em nosso hospital entre 2011 e 2014 foram incluídos. Edwards SAPIEN XT Válvula Cardíaca Transcatheter foi usado. A melhoria do funcionamento da válvula e do coração foi avaliada, bem como mortalidade em 30 dias e as principais complicações de acordo com a definição VARC-2.Resultados:Um total de 10 procedimentos Tavi com o sistema balão-expansível foram realizados em nosso hospital, dos quais 9 foram transfemorais e 1 foi transapical. A idade média foi de 76 anos, e os STS mediana marcar e Logistic EuroSCORE (%) foram de 8,9 e 16,2. A implantação foi realizada com sucesso em todos os pacientes, apenas 2 pacientes tiveram vazamento paravalvar leve. Não houve um futuro implante valvar. Além disso, mortalidade em 30 dias ou complicações não foram relatadas. Seguindo o procedimento de implante percutâneo da válvula aórtica, as válvulas cardíacas e funções melhoraram significativamente. Durante o período de acompanhamento de 3-34 meses, um paciente morreu de câncer de pulmão 13 meses após a operação.Conclusão:Esta experiência inicial apresentou elementos de prova preliminar para a segurança e eficácia do procedimento implante percutâneo da válvula aórtica com o sistema balão-expansível no mundo em desenvolvimento com crescente envelhecimento da população.


Subject(s)
Aged , Female , Humans , Male , Aortic Valve Stenosis/therapy , Balloon Valvuloplasty/methods , Transcatheter Aortic Valve Replacement/methods , Angiography , Aortic Valve Stenosis , China/epidemiology , Retrospective Studies , Treatment Outcome , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/mortality
SELECTION OF CITATIONS
SEARCH DETAIL